UL Listed / FM Approved Fire Pump Control Panel For Fire Fighting Usage
The Diesel Plus Controller is a comprehensive, multi-function microprocessor based Fire Pump Controller.
Designed to meet the needs of markets worldwide, the Diesel Plus controller is certified by the following authorities:
Underwriters Laboratories (UL), Factory Mutual Research (FM), Canadian Standards Association (CSA), New York
Department of Buildings (NYSB), and meet CE and U.B.C. / C.B.C. Seismic approval requirements
System History:
The Diesel Plus controller will record the last 10,000 alarm/ status messages in its memory that can be viewed on
the main display, saved to a USB storage device, or viewed on the optional embedded webpage. In order to view
the messages on the display press the up or down arrow buttons from the main screen until the display shows “Display
Message History”. Press the Ack. Alarm button to view the message history. The display will now show three messages
at a time. Pressing the up or down arrow buttons will allow navigation showing the most recent message to the oldest
message. Refer to Appendix L for common messages and their meaning. Refer to Section 7 to save the message history
to a USB storage device or to view the message history on the optional embedded webpage.
Weekly Exerciser Test
Turn the mode selector switch to the “OFF” position. To test the Weekly Exerciser, preprogram the controller to initiate the
test at a time suitable to the user. Turn the mode selector switch to the “AUTO” position. At the programmed time and date
the drain valve solenoid will open. The Engine will crank and start. The “Engine Run” annunciator will illuminate.and the drain
valve solenoid will close. Press the STOP pushbutton. The engine will stop. Reprogram Weekly Exerciser for normal operation.
Automatic Start Test
Turn the mode selector switch to the “AUTO” position. Ensure that water pressure is available and the LCD display on the
display panel is reading the system pressure correctly. Decrease water pressure below the programmed start point. The
controller will begin its cranking cycle. Should the engine fail to start after 6 crank and rest cycles, the audible alarm will
sound and the “Fail To Start” annunciator will illuminate. Turning the mode selector switch to the “OFF” position will silence
the alarm. When engine starts, “Engine Run” annunciator illuminates.
Increase water pressure above programmed START point. Press the stop pushbutton on the enclosure. If the pressure is
satisfied, and there are no other starting conditions the engine will stop. OR If Auto Stop is programmed for "On", the engine
will stop automatically after the Run Period Timer times out and pressure is satisfied. The RPT is programmed by the user; the
factory setting is 30 minutes. If the Sequential Timer is > 0 seconds, automatic start will be delayed by the number of seconds
programmed.
Wuhan Spico Machinery & Electronics Co., Ltd.
Wuhan Spico Machinery & Electronics Co., Ltd.(Hereinafter referred to as SPICO) is the Wuhan
office of CNP NM Fire-fighting System Co.,Ltd (Hereinafter referred to as NM Fire). SPICO mainly resp-
onsible for product promotion,export declaration and foreign exchange collection of overseas orders.NM
Fire is the subsidiary of Nanfang Zhongjin Environment Co.,Ltd, which islocated in Hunan Changsha
Economic and Technological Development Zone, mainly produceand sell Diesel engine &Motor fire pump
groups ,controllers and fire pumps which are in accordance with domestic & international standards and have
gotten related certifications .
With the help of multi-national engineers with more than 20 years of professional experience, the NMFIRE
technical team fully understands the technical requirements of fire fighting systems. They have overcome
difficulties, conquered technical aspects, created China's first in this industry and opened up a new market
for China's fire fighting research andtechnology.
The company’s mission is to protect the community fire safety, in line with the spirits of “integrity,
win-win”,glad to provide high cost-effective products and high-quality service for our customers.
Fire fighting is the last protection for life and property. These include strict technical, quality and testing requirements
for fire fighting equipment that are specified in the UL/FM product standard.
Under the premise of fully learning and understanding these standards, our company has invested huge sums of money
and energy in research and development of new products. Many innovative technologies have been developed through
product R&D. The pumps and diesel engines have reached the level of first class in the world. The research and
development of these two critical products has put an end to the long history in the domestic marketplace of taking
non-certified ordinary water pumps and diesel engines and using them in life safety applications. This has also completely
changed the domestic technology level of this industry and has allowed NM FIRE to lead the market
SPICO ENDORSEMENT:
S: SERVANT ETHICS & SERVICE SPIRIT
Keep the complicated and tedious to ourself, but the simple and convenient for our partners.
P: PARTNERSHIP & PROFESSIONAL
Treat each other as partner with deep feeling focus on sustainable development.
I: INTERNATIONALIZATION,INTERACTION & IMPROVEMENT
Global vision, local action. Interaction builds loyalty.
CO: CUSTOMER-ORIENTED APPROACH
Start by meeting the customer obvious needs, follow by continuously deepening and exploring potential customer demand,
meanwhile, plant the philosophy into our soul.