Powersafe series Online LF UPS 1-30kVA
1. System Introduction
PS II Series UPS is a full-digitized with European Cortex-M3 MCU (STM32F103RCT6 )controlled single phase input/single phase output or 3 phase input/single phase output online UPS. It provides reliable, stable, and constant AC power for computer equipment, telecommunication devices, precision equipment/instrument, and network termination equipment (NTE). UPS systems protects all these devices from losing data or information due to power outage, interruption or disruption to truly and comprehensively solve power issues, such as power outage, power surge, voltage sags, temporary over-voltage, temporary under voltage, frequency offset, power disturbances, switching transients, and harmonic wave distortion.
2.Syetem Features
2.1High Performance Index
◆ Advanced SCR Rectifier and IGBT Inverter Technology. Online 1/1 or 3/1 double conversion structure.
◆ Adapt with output isolated transformer technology to fit 200,220,230,240Vac,50/60Hz Grid Systems;
◆ Wide Input Range from Single Phase 160-280Vac,3 Phase 286-475Vac ,50/60 Hz±5%,High Adaptive Capacity to Mains Grid
◆ High Overload Ability -- surge current protection technology to carry sudden impact for 0% to 100% load immediately without transfer to bypass;
◆ Overall Efficiency 85%. 98% under ECO Mode;
◆ Full-digitized Non-master slave parallel redundancy technology. Parallel circumfluence ≤5%;
◆ Intelligent Charging Design. It equips with BAT low/over charged sensor to protect the charger. Real-time diagnosis on Battery status and response data simultaneously;
◆ Large Color Dot-matrix LCD+LED Screen with multi-functional keyboard to check system parameters, such as fault histories, operational statuses self-diagnosis periodically discharge settings, etc.
◆ Battery Self-testing can be done on the LCD directly. Battery Capacity, UPS working mode (Online or ECO) can be set on the screen. All history faults and statistics can be seen on the screen to help user analyze the working summary of the UPS.
◆ Monitoring can be done by WAN/LAN SNMP adapter or Cloud Monitoring Adapter. UPS equips with RS232, USB, EPO ports, and can choose RS485 and Dry-contact as optional accessories.
◆ Front to Rear Ventilation Design to reduce the defective rate of the product.
◆ Smart Size.
2.2. Safe and Reliable
◆ MCU control to operate all power conversion sessions during the operations, which has higher system reliability than traditional UPS systems.
◆ Output Isolated Transformer Built-in. It can reduce impacts and interferences from Load Harmonic Wave Current and N-Wire Voltage.
◆ Special Design on battery connectors to save the shock hazards from mis-operation;
◆ 90% of system components are from international brands. All devices has been aged and fully tested for at least 24 hours before leaving the factory.
3. Rich Optional Accessories
The System can use SNMP Network Adapter, RS485/Dry Contact, USB port,and EPO function to build up a remote control and monitoring system.
4. Application Type
The System is designed for small and medium important equipment systems, such as small and medium commercial network equipment, small data center, important medical equipment, manufacturing process control system and communication equipment.
5. Technical Point
◆ MCU control provides higher system reliability than traditional UPS systems.;
◆ Wide Input Voltage and Frequency Range.;
◆ Non-Master Slave digital parallel redundancy feature;
◆ Advanced Battery Management system;
◆ High Overload Ability;
◆ Dot Matrix Color Screen for friendly ;
◆ Online Double Conversion technology with output isolated transformer
◆ Smart Size compared to the same size of the UPS in the market. All UPS equipped with wheels.
6,Specs
1/1 Phase, 3/1 Phase
Model | PS01S/PS01L | PS02S/PS02L | PS03S/PS03L | PS06S/PS06L | PS08L | PS10L | PS150L | |||||||
Capacity | 1KVA/0.8KW | 2KVA/1.6KW | 3KVA/2.4KW | 6KVA/4.8KW | 8KVA/6.4KW | 10KVA/8KW | 15KVA/12KW | |||||||
Host Machine Specification | ||||||||||||||
Technology | Online Double Conversion | |||||||||||||
UPS Structure | Low Frequency with Output Isolated Transformer | |||||||||||||
Overall Efficiency (AC-AC ) | > 85% | |||||||||||||
Noise(In 2 meters) | < 50dB | |||||||||||||
Working Temp. | -10-40℃ | |||||||||||||
Storage Temp | -25-60℃ (Without Batteries) | |||||||||||||
HumiPSty | < 95%Non-Condensing | |||||||||||||
Safety Standard | IEC62040 | |||||||||||||
EMC/EMI Standard | EN 50091-2 | |||||||||||||
Parallel Redundancy | Available | |||||||||||||
Protections | Overload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low | |||||||||||||
DC Start | Available | |||||||||||||
Generator Compatibility | Available | |||||||||||||
Display | LCD display: Multi-Language with all kinds of messages. Input Output Status, ECO Mode Settings,INV. Temp. TX Status Calendar, Time, Serial Number, Model, Structure, History Logs, Battery Test. LED Indicators: UPS States Indicator | |||||||||||||
Mute | Auto | |||||||||||||
Cabinet Standard | IP20 | |||||||||||||
Cooling System | Intelligent Speed Control Cooling Fan | |||||||||||||
Elevation | <1000M Without Derated | |||||||||||||
Rectifier Specification | ||||||||||||||
Nominal Voltage | 220Vac | |||||||||||||
Input Voltage Range | 160-280Vac | |||||||||||||
Input Freq. Range | 50 Hz±5%(45-65Hz) | |||||||||||||
Soft-Start | >20 Seconds | |||||||||||||
Output Specification | ||||||||||||||
Output Voltage | 220Vac | |||||||||||||
Output PF | 0.8 | |||||||||||||
Output Voltage Regulation | 220Vac±1%(Static Load ),220Vac±2% (50~0% Sudden Change) | |||||||||||||
Output Freq | 50Hz±0.1%(BAT Mode) | |||||||||||||
PSstortion | < 1%(100% Linear Full Load),< 3%(100% Non-Linear Full Load) | |||||||||||||
Frequency Tracking Range | 46-54Hz | |||||||||||||
Output Waveform | Pure Sine Wave | |||||||||||||
Overload | 125% More than 1 Min;> 150% More than 300ms | 125% More than 10 Mins;> 150% More than 1 Min | ||||||||||||
Crest Ratio | 3∶1 | |||||||||||||
Short-Circuit | Circuit Auto Protection,Output Voltage/Current 0 | |||||||||||||
Output Abnormal | INV. Output Auto-Locked Protection | |||||||||||||
Bypass Specification | ||||||||||||||
Static Bypass Transfer Time | 0ms(Static Switch Phase Lock Control Technology) | |||||||||||||
Static bypass Overload Ability | 200%~5 Minutes;1000%~10 Seconds | |||||||||||||
Frequency Range | ±1Hz,±2Hz,±3Hz Adjustable | |||||||||||||
Manual Maintenance Bypass | / | Available | ||||||||||||
Alarm Specification | ||||||||||||||
Alarm | Utility Power Fault, BAT Voltage Low, Overload,UPS Fault | |||||||||||||
Mute | Auto | |||||||||||||
Battery Specification | ||||||||||||||
Type | Sealed Lead Acid Maintenance Free | |||||||||||||
Rated Volts | 72Vdc | 72Vdc | 96Vdc | 192Vdc or 96 | 192Vdc | |||||||||
Charging Current | Standard/Built-in Model 1A,Long backup/External Battery Model 5A | |||||||||||||
BAT Low | Shutdown Protection | |||||||||||||
Communication Specification | ||||||||||||||
Communication Port | Rs232 (Std.);/SNMP/RS485/ Dry Contact (Optional Accessory) | |||||||||||||
Remote Software | Multi-functional Monitoring System, Online and BAT Mode Status, BAT Fault, Remote Control | |||||||||||||
Physical Parameters | ||||||||||||||
Size mm (W×D×H) | STD. Model | 220×510×395 | 220×610×635 | / | ||||||||||
EXT Model | 220×610×475 | 220×610×715 | 310×655×790 | |||||||||||
Weight Kg | 34/25 | 40/26 | 46/29 | 105/76 | 85 | 95 | 125 |
Note:S in the model refers to standard/built-in battery model. L refers to Long backup/External Battery Model.
1/1 Phase, 3/1 Phase
Model | PS60L31 | PS100L31 | PS150L31 | PS200L31 | PS300L31 | |
Capacity | 6KVA/4.8KW | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | ||
Host Machine Specification | ||||||
Technology | Online Double Conversion | |||||
UPS Structure | Low Frequency with Output Isolated Transformer | |||||
Overall Efficiency (AC-AC ) | > 85% | |||||
Noise(In 2 meters) | < 50dB | |||||
Working Temp. | -10-40℃ | |||||
Storage Temp | -25-60℃ (Without Batteries) | |||||
Humidity | < 95%Non-Condensing | |||||
Safety Standard | IEC62040 | |||||
EMC/EMI Standard | EN 50091-2 | |||||
Parallel Redundancy | Available | |||||
Protections | Overload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low | |||||
DC Start | Available | |||||
Generator Compatibility | Available | |||||
PSsplay | LCD display: Multi-Language with all kinds of messages. Input Output Status, ECO Mode Settings,INV. Temp. TX Status Calendar, Time, Serial Number, Model, Structure, History Logs, Battery Test. LED Indicators: UPS States Indicator | |||||
Mute | Auto | |||||
Cabinet Standard | IP20 | |||||
Cooling System | Intelligent Speed Control Cooling Fan | |||||
Elevation | <1000M Without Derated | |||||
Rectifier Specification | ||||||
Nominal Voltage | 380Vac+N+W 3Phase | |||||
Input Voltage Range | 286-475Vac | |||||
Input Freq. Range | 50 Hz±5% | |||||
Soft-Start | >20 Seconds | |||||
Output Specification | ||||||
Output Voltage | 220Vac | |||||
Output PF | 0.8 | |||||
Output Voltage Regulation | 220Vac±1%(Static Load ),220Vac±2% (50~0% Sudden Change) | |||||
Output Freq | 50Hz±0.1%(BAT Mode) | |||||
Distortion | < 1%(100% Linear Full Load),< 3%(100% Non-Linear Full Load) | |||||
Frequency Tracking Range | 46-54Hz | |||||
Output Waveform | Pure Sine Wave | |||||
Overload | 125% More than 10 Mins;> 150% More than 1 Min | |||||
Crest Ratio | 3∶1 | |||||
Short-Circuit | Circuit Auto Protection,Output Voltage/Current 0 | |||||
Output Abnormal | INV. Output Auto-Locked Protection | |||||
Bypass Specification | ||||||
Static Bypass Transfer Time | 0ms(Static Switch Phase Lock Control Technology) | |||||
Static bypass Overload Ability | 200%~5 Minutes;1000%~10 Seconds | |||||
Frequency Range | ±1Hz,±2Hz,±3Hz Adjustable | |||||
Manual Maintenance Bypass | Available | |||||
Alarm Specification | ||||||
Alarm | Utility Power Fault, BAT Voltage Low, Overload,UPS Fault | |||||
Mute | Auto | |||||
Battery Specification | ||||||
Type | Sealed Lead Acid Maintenance Free | |||||
Rated Volts | 192Vdc | 384Vdc | ||||
Single Group Qty. | 16PCS | 32PCS | ||||
Charging Current | Standard/Built-in Model 1A,Long backup/External Battery Model 5A | |||||
BAT Low | Shutdown Protection | |||||
Communication Specification | ||||||
Communication Port | Rs232 (Std.);/SNMP/RS485/ Dry Contact (Optional Accessory) | |||||
Remote Software | Multi-functional Monitoring System, Online and BAT Mode Status, BAT Fault, Remote Control | |||||
Physical Parameters | ||||||
Size mm (W×D×H) | EXT Model | 310×655×790 | ||||
Net Weight (Kg) | 68 | 70 | 98 | 115 | 125 | |
Gross Weight (Kg) | 76 | 79 | 108 | 125 | 135 |
Note:S in the model refers to standard/built-in battery model. L refers to Long backup/External Battery Model.
Shenzhen HRD SCI&TECH CO.,Ltd
About HRD ,founded in 2010, after more than 14 years fast development,HRD has grown into a large leading professional UPS manufacturer with ISO9001:2015 , ISO14001,ISO18001 certified
Based on strong high level professional R&D team with own core technology in both hardware and software,HRD specially focus on producing middle and high level quality AC UPS, Industrial Charger&DC UPS, AC source, inverters and customized power supply based on OEM and ODM.
Our power products capacity range is from 600VA to 800KVA, and have gained more than 60nos inventive and innovative patents.Also we have become the only UPS manufacturer from China,which is able to produce super reliable large capcaity indsutrial LF UPS up to 800kVA (parallel up to 8units)!
So far our products have been exported to more than 40 countries , preferred by many quality clients ,including by world-famous brands etc( EATON, SIMENS, AEG etc... )
The high quality UPS, Inverter ect power products are also successfully and widely used for the Chinese Army power system and let’s become one of the two appointed UPS supplier of the People’s Liberation Army General Armaments Department and appointed supplier of the central government of China ,too.
Our main products details as below:
For 220/230/240Vac,Power grid | |
PEII series 3phase Online LF UPS 10-800kVA, output PF 0.9 | |
H6000-Marine Industrial UPS 3:3phase 10-600kVA | |
PWM series 3phase Online HF UPS 10-60kVA, output PF1.0 | |
HQM series Modular UPS 25-840kVA, output PF 1.0 | |
PC Max series Online HF UPS 1-20kVA, output PF1.0 | |
PC Max Rack mount Online HF UPS 1-10kVA, output PF1.0 | |
HC series Line interactive UPS 1KVA-5kVA, output PF0.8 Smart Power Series Offline UPS 600VA-3000VA,Output PF0.6 | |
Hybrid Solar inverter 1kw-10kW, transformerless | |
R7000 Series Industrial Charger&DC UPS | |
Battery: Lead acid, Gel ,Lithium Battery and CSB battery | |
For 110/120/127Vac,60Hz Power grid | |
PEAII (America)3phase Online LF UPS 10-200kVA, output PF 0.9 | |
Powerwell Max (America)3phase Online HF UPS 10-30kVA, Output PF 0.9 | |
ZYA Modular UPS 60kVA-300kVA,output PF 0.9 | |
PCM TX series Split phase UPS 6-10kVA, Output PF 1.0 | |
HC series line interactive UPS 1-3kVA, output PF0.8 | |
RT rack Mount Line interactive UPS 1-3kVA, output PF0.8 | |
Smart Power Series Offline UPS 600VA-3000VA,Output PF0.6 | |
Accessory: SNMP card,Dry contact board,CSB battery, battery cabinet ect... |
|
Thanks to 2 large manufacturing bases of more than 20000 square meters in Bao’an District Shenzhen and Foshan Guangdong ,we make sure to deliver each high quality product on time to our global clients.
With the core competitive power behind HRD product --Quality, Service and Efficiency, has powerfully assisted HRD winning more and more global clients’ preference.
On the way of HRD’s rapid development, we have witnessed each development milestone with our clients.We look forward to creating and witnessing more legendary with you in power field!
We warmly welcome and expect your visit to HRD to negotiate muthual benefical business cooperation in long term!
Mission: Produce high quality energy products and provide complete power solution to worldwide partners for middle and high end market;
Vision:To be a world-class company in energy solution provider.